LRS-50W Switching Power Supply

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Zhejiang
Validity to: Long-term effective
Last update: 2019-04-16 15:53
Browse the number: 352
inquiry
Company Profile
 
 
Product details

LRS-50W Series Ultra Thin Single Switching Power Supply

Features:

· Universal AC input / Full range

· Withstand 300VAC surge input for 5 second

· Miniature size and 1U low profile, low weight

· Protections: Short circuit / Overload / Over voltage

· Cooling by free air convection

· No load power consumption<0. 5W

· Operating altitude up to 5000 meters (Note6)

· LED indicator for power on

· 100% full load burn-in test

· High efficiency, long life and high reliability

· 3 years warranty


Model

LRS-50-5

LRS-50-12

LRS-50-15

LRS-50-24

LRS-50-36

LRS-50-48

Output

DC voltage

5V

12V

15V

24V

36V

48V

Rated current

10A

4. 2A

3. 4A

2. 2A

1. 45A

1. 1A

Current range

0~10A

0~4. 2A

0~3. 4A

0~2. 2A

0~1. 45A

0~1. 1A

Rated power

50W

50. 4W

51W

52. 8W

52. 2W

52. 8W

Ripple & noise

100mVp-p

120mVp-p

120mVp-p

150mVp-p

200mVp-p

200mVp-p

DC voltage ADJ. range

±10%

±10%

±10%

±10%

±10%

±10%

Voltage tolerance Note. 3

±3%

±2%

±1%

±1%

±1%

±1%

Line regulation Note. 4

±0. 5%

±0. 5%

±0. 5%

±0. 5%

±0. 5%

±0. 5%

Load regulation Note. 5

±2%

±1%

±0. 5%

±0. 5%

±0. 5%

±0. 5%

Setup, rise, hold up time

800ms, 30ms, 30ms/ 230VAC (full load)

Input

Voltage range

90~264VAC,127~373VDC

Frequency range

47~63HZ

AC current

0. 95A/ 115VAC 0. 56A/ 230VAC

Inrush current

Cold start 45A/ 230VAC

Efficiency

83%

86%

87%

88%

89%

90%

Leakage current

<0. 75mA/ 240VAC

Protection

Overload

Rated output power 110%~150% start over load protection

Protection type: hiccup mode, auto-recovery after fault condition is removed

Over voltage

Rated output voltage 115%~135% Start over voltage protection

Protection type: hiccup mode, auto-recovery after fault condition is removed

Environment

Working temp, humidity

-30℃~+70℃ (Please refer to "derating curve")

20%~90% RH Non-condensing

Storage temp, humidity

-40℃~+85℃, 10%~95% RH non-condensing

Withstand vibration

10~500HZ, 2G 10min/1cycle, period for 60 minutes, each axes

Safety

Withstand voltage

I/P-O/P: 1. 5KVAC I/P-FG: 1. 5KVAC O/P-FG: 0. 5KVAC

Isolation resistance

I/P-O/P, I/P-FG, O/P-FG: 100M ohms/ 500VDC

Fit standard

Safety standards

Compliance to UL60950-1, TUV EN60950-1, GB4943

EMC emission

Compliance to EN55022 (CISPR22) Class A, GB9254 Class B, EN55014, EN61000-3-2, 3

EMC immunity

Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-1

Others

Dimension

99*82*30mm (L*W*H)

Weight / packing

0. 21kg/ 60pcs/ 13. 6kg/ 0. 025m³/ 0. 88CUFT

MTBF

≥630K hrs min. MIL-HDBK-217F (25℃)

Note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. Line regulation is measured from low line to high line at rated load.

5. Load regulation is measured from 0% to 100% rated load.

6. The ambient temperature derating of 5℃/1000 m is needed for operating altitude greater than 2000m (6500ft).

7. The power supply is considered as a component which will be installed into a finalequipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests.


http://www.honwhim.com/